PRODUCT DESCRIPTION

Product name: 3M N95 mask 1860

• Selling unit: Carton

• Specification: 20 pieces/box - 6 boxes/carton

• Size:

• Type: Masks

• Material, substance:

• Uses: Used in medicine, protecting the respiratory tract for the wearer from fine dust particles in the air.

• Features: They have the ability to catch and block saliva, viruses and bacteria from dust, factory emissions, vehicles, dust, and ash from household cooking, restaurants, etc.

NIOSH N95 standard The FDA standard 3m 1860 mask can be used as a mask in medical surgical application.

Uses: 3M1860s masks help protect from biological entities in the form of particles, resistant to substances (such as blood, ...)

Features of 3m mask 1860 N95
NIOSH approves rating as N95 . respirator
FDA approved for use as surgical masks
Liquid resistance 80 mmHg
Class I flammability mask rating
Adjustable nose clip
Braided and pinned headband
Gas masks and surgical masks

PRODUCT DETAILS

Face mask 1860 helps protect the respiratory tract for the wearer from fine dust particles in the air. This respirator meets CDC standards for exposure control of Mycobacterium tuberculosis (a virus).

This is a line of disposable masks against fine dust particles, they are made to help the wearer avoid exposure to certain airborne particles including those produced by electrocautery, laser surgery and medical equipment. other medical instruments.

Facemask 1860 A surgical mask that, when worn, can protect against flow and blood splashes or other infectious materials.

Particle respirators 1860  are personal protective equipment (PPE) intended primarily to protect healthcare workers by reducing exposure to harmful airborne particles that are small enough to be inhaled – usually airborne particles. less than 100 microns in size. These include airborne particles that can contain microorganisms, such as Bacillus anthracis, Mycobacterium tuberculosis, molds, and viruses that cause severe acute respiratory distress such as Syndrome (SARS) and Influenza. And now 3M 1860 masks and 1860s masks are used to prevent Corona Virus for first-line doctors to care for and treat infected cases.

Material of 3m mask 1860 N95

  • Straps: Braided Polyisoprene
  • Mask frame (Staples): Steel
  • Nose Clip: Aluminum
  • Nose Foam: Polyurethane Foam
  • Filter (Filter): Polypropylene/Polyester
  • Seo part (Shell): Polypropylene
  • Outer part (Coverweb) :Polypropylene
  • In particular, the 3m 1860 mask does not contain rubber components.
  • The maximum weight of the product is 11.3g

Approved standards

  • NIOSH approved N95 respirator: NIOSH US N95 standard
  • Meets NIOSH 42 CFR 84 N95 requirements for a minimum 95% filtration efficiency against solid and liquid aerosols that do not contain oil: Meets NIOSH 42 CFR 84 N95 standard for filtration of 95% oil-free solids and liquids.
  • NIOSH approval number: TC-84A-0006: NIOSH standard TC-84A-0006
  • FDA cleared for use as a surgical mask: Meets FDA standards for use in medical examination and surgery
  • Health Canada Class I medical device: Health Canada's leading medical device standard
  • Bacterial Filtration Efficiency F2101 >99% BFE: More than 99% antibacterial standard.
  • OSHA Assigned Protection Factor (APF) 10: Standard OSHA Assigned Protection Factor (APF) rating 10
  • Australia TGA approved: Australia's TGA standard.

Instructions for using the mask 3m 1860
The following instructions must be followed to use the 3m 1860 mask. Before wearing the mask, make sure your hands are clean.

All components of the mask should be checked and made sure that it is not torn or damaged during use

  1. Hold the mask inside the palm of one hand with the nose tip of the mask at the tip of the finger, allowing the headband to hang freely under the hand.
  2. Keep the mask under the chin, with the nose of the mask facing up.
  3. Locate the top strap across the top of the head and the lower strap to be placed under the ears.
  4. Make sure the belt is not twisted.
  5. Using both hands, press down on the nose profile of the mask to ensure that the mask is firmly attached and that no air is allowed to enter.
  6. Make sure the mask is properly fitted to your face before engaging in your work.

Note

  • Suitable for your working environment
  • Worn according to instructions
  • Wear in all phases of exposure;
  • Replace when necessary.
  • Suitability should be checked before assigning a respirator to an individual. If you cannot achieve a fit then do not enter the contaminated area.
  • Test the mask before each use to make sure it is in good working condition. Inspect all parts of the mask for signs of damage excluding the two straps, noseclip, nose foam. Respirators should be disposed of immediately when damage or missing parts are observed. Respirators should be disposed of immediately upon observation of damaged or missing parts.
  • Leave the contaminated area immediately and contact a supervisor if dizziness, irritation or other discomfort occurs.
  • Dispose of used product according to applicable regulations.
  • All masks should be used in accordance with local regulations direction.
  • Do not alter, repair, wash and abuse or misuse the respirator.
  • Do not use on people with beards or facial hair or other similar circumstances that prevent securely between the face and the mask.
  • Respirators can help protect the wearer's lungs against certain airborne contaminants; however, it will not prevent penetration of other glands such as skin or eyes, which will require additional personal protective equipment (PPE).
  • The mask is intended for professional/professional use by adults who are well trained in its use and limitations. The respirators are not designed for use by children.
  • People with compromised respiratory systems, such as asthma or emphysema, should consult a doctor and complete a medical evaluation before use.
  • Maximum operating temperature: +50 degrees Celsius.
  • The filtering efficiency of the mask may decrease in the presence of oil mist.
  • Preserve
  • The shelf life of the unopened product is five (5) years from the date of manufacture when stored in the temperature range of -20°C to +30°C and at a relative humidity of less than 80%.
  • The expiration date is marked on the product packaging.
  • When using the product for the first time, always check if the product is within the use-by date range